Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Ariyoshi, Gen; Obayashi, Hironari; Sasa, Toshinobu
Journal of Nuclear Science and Technology, 59(9), p.1071 - 1088, 2022/09
Times Cited Count:1 Percentile:31.61(Nuclear Science & Technology)Electromagnetic induction method is one of the effective techniques for local velocity measurement in heavy liquid metals. Ricou and Vives' probe and Von Weissenfluh's probe are famous instrumentations using a permanent magnet. However, sensitivity and measurement volume of the probes show unexpected variation since demagnetization of the magnet is occurred by temperature increase up to the Curie temperature. In this study, electromagnetic probe incorporating a miniature electromagnet was newly developed to overcome such unexpected variation. The diameter and the length of the sensor was 6 mm and 155 mm, respectively. The sensitivity and the measurement volume of the probe were assessed by measurement of local velocity of flowing mercury in a square channel. To clarify the validity for the measured velocity profiles, numerical velocity profiles were calculated and compared with experiment. And the validity for the measured velocity profiles were confirmed by calculated result.
Meigo, Shinichiro; Noda, Fumiaki*; Fujimori, Hiroshi*; Ikeda, Yujiro
Proceedings of ICANS-XVI, Volume 3, p.967 - 976, 2003/07
In J-PARC project, spallation target is irradiated by 3 GeV proton beam of 1 MW. Due to hands on maintenance for the proton beam lines, loss of proton beam is limited less than 1 W/m. Since it is difficult to predict the phase space distribution of the proton beam, we decided that the beam line have to be larger acceptance for 324 mrad, which is determined by the collimator located in the synchrotron. Distortion of proton beam is caused by the by the instability of angle at the extraction of 3-GeV synchrotron, miss alignment of the magnet, and un-uniformity of the magnet field. In this study, the distortion is calculated. In order to fit the conditions, the stability of extraction angles should be kept smaller than 0.2 mrad. As for the magnetic field, it is found that the uniformity should be kept better 5x10 and 2x10 for bending and quadruple magnets, respectively. It is also found the error of alignments should be limited smaller than 1.0 mm and 1.0 mrad.
Nishitani, Takeo; Shikama, Tatsuo*; Sugie, Tatsuo; Kasai, Satoshi; Ishitsuka, Etsuo; Kawamura, Hiroshi; Kakuta, Tsunemi; Yagi, Toshiaki; Tanaka, Shigeru; Narui, Makoto*; et al.
JAERI-Research 2002-007, 149 Pages, 2002/03
no abstracts in English
Nishitani, Takeo; Shikama, Tatsuo*; Fukao, M.*; Matsuo, H.*; Snider, R.*; Broesch, J.*; Sagawa, Hisashi; Kawamura, Hiroshi; Kasai, Satoshi
Fusion Engineering and Design, 51-52(Part.B), p.153 - 158, 2000/11
Times Cited Count:10 Percentile:54.14(Nuclear Science & Technology)no abstracts in English
*; Neyatani, Yuzuru; Abe, Mitsushi*; Kasai, Satoshi; Nagashima, Akira
Diagnostics for Experimental Thermonuclear Fusion Reactors 2, p.545 - 548, 1998/00
no abstracts in English
; *; Ara, Katsuyuki
JAERI-Research 96-058, 25 Pages, 1996/10
no abstracts in English
*; *; *; *; *; Matoba, Toru
JAERI-Tech 95-041, 12 Pages, 1995/08
no abstracts in English
Neyatani, Yuzuru; *; Yokomizo, Hideaki
Japanese Journal of Applied Physics, 27(12), p.2398 - 2403, 1988/12
Times Cited Count:0 Percentile:0.01(Physics, Applied)no abstracts in English